– 470 – NWA-008845-001 Rev.5.0
32ch1008.fm
For MCI with AP00 (PN-AP00-B/PN-AP00-D with MRCA program)
[Series 3300 software required]
DESCRIPTION DATA
Set interface condition for PN-AP00-B/
PN-AP00-D with MRCA program RS port.
When you set CMDD01, the following initial
data is set to specified port as the interface con-
dition.
Data Speed: 9600 bps
Stop Bit Length: 2 bits
Data Length: 7 bits
Parity: No Parity
Station Address (SA): 0
Unit Address (UA): !
Send the text to the VMS when the AP00
card is reset.
6-digit station number in the message for-
mat to communicate with the VMS/Format
without ANI
Timer for detecting the end of block: 1 sec-
ond
Guard timer between text: 512-640 ms.
(1)
(2)
100 (Port 0)
101 (Port 1)
102 (Port 2)
103 (Port 3)
10: MCI
To change the interface condition of each port
set by CMDD01, assign the attribute data, ac-
cording to the VMS.
(1)
(2)
X01: Data Speed for Port 0-3
X: 0-3: Port 0-3
1 : 300 bps
2 : 1200 bps
3 : 2400 bps
4 : 4800 bps
5 : 9600 bps
6 : 19200 bps
(1)
(2)
X02: Stop Bit Length for Port 0-3
X: 0-3: Port 0-3
0: 1 bit
1 : 1.5 bits
2: 2 bits
F