ā 510 ā NWA-008845-001 Rev.5.0
32ch1008.fm
To use a DSS Console with the D
term
Attendant Position, add the following programming.
DESCRIPTION DATA
Assign the DSS Console number to the re-
quired LEN.
(1)
(2)
000-763: LEN
E100-E131 : DSS Console No.
For PIM0/1: E100-E107
For PIM2/3: E108-E115
For PIM4/5: E116-E123
For PIM6/7: E124-E131
Assign the DSS Console number to the re-
quired LEN.
[Series 3200 R6.2 software required]
NOTE: When using Series 3500 software or
later, for the FP No. 00-03 of MP
built-in FP/FP card of Main Site
and MP built-in FP of Remote Site,
the DSS console number (E100-
E131) can be assigned without limit
as shown right.
(1)
(2)
XX ZZZ: LEN
XX : 00-59: FP No.
ZZZ: 000-127: Port No.
E100-E131 : DSS Console No.
For FP No. 00: E100-E107
For FP No. 01: E108-E115
For FP No. 02: E116-E123
For FP No. 03: E124-E131
Assign the My Line number of the Attendant
Position associated with each DSS Console.
(1)
(2)
00-31: DSS Console No. assigned by
CM10/CM14 (E100-E131)
X-XXXXXXXX: My Line No. of Atten-
dant Position
Assign station numbers to the DSS keys.
Assign the MW, DND, NT keys as function
keys.
(1)
(2)
For DSS key:
DSS Console No. (00-31) + + DSS key
No. (00-59)
X-XXXXXXXX: Station No.
(1)
(2)
For Function key:
DSS Console No. (00-31) + + DSS key
No. (57-59)
F1049: Message Waiting
F1053: Do Not Disturb
F0043: Night Key
START
CM10
CM14
CM96
CM97
,
,
END