Remote Commands
R&S
®
FSW
1111User Manual 1173.9411.02 ─ 43
<p> Power sensor index
Parameters:
<State> ON | OFF | 0 | 1
OFF | 0
Switches the function off
ON | 1
Switches the function on
Example:
CALC:PMET2:REL:STAT ON
Activates the relative display of the measured value for power
sensor 2.
FETCh:PMETer<p>?
This command queries the results of power sensor measurements.
Suffix:
<p>
.
Power sensor index
Usage: Query only
READ:PMETer<p>?
This command initiates a power sensor measurement and queries the results.
Suffix:
<p>
.
Power sensor index
Usage: Query only
[SENSe:]PMETer<p>:DCYCle[:STATe] <State>
This command turns the duty cycle correction on and off.
Suffix:
<p>
.
Power sensor index
Parameters:
<State> ON | OFF | 0 | 1
OFF | 0
Switches the function off
ON | 1
Switches the function on
Example:
PMET2:DCYC:STAT ON
Manual operation: See "Duty Cycle" on page 378
[SENSe:]PMETer<p>:DCYCle:VALue <Percentage>
This command defines the duty cycle for the correction of pulse signals.