Remote Commands
R&S
®
FSW
1155User Manual 1173.9411.02 ─ 43
CALCulate<n>:MARKer<m>:AOFF
This command turns off all markers.
Suffix:
<n>
.
Window
<m> Marker
Example:
CALC:MARK:AOFF
Switches off all markers.
Manual operation: See "All Markers Off" on page 522
CALCulate<n>:MARKer<ms>:LINK:TO:MARKer<md>
<State>
This command links normal marker <m1> to any active normal marker <m2>.
If you change the horizontal position of marker <m2>, marker <m1> changes its hori-
zontal position to the same value.
Suffix:
<n>
.
Window
<ms> source marker, see Marker
<md> destination marker, see Marker
Parameters:
<State> ON | OFF | 0 | 1
OFF | 0
Switches the function off
ON | 1
Switches the function on
Example:
CALC:MARK4:LINK:TO:MARK2 ON
Links marker 4 to marker 2.
Manual operation: See "Linking to Another Marker" on page 344
CALCulate<n>:MARKer<m>[:STATe] <State>
This command turns markers on and off. If the corresponding marker number is cur-
rently active as a delta marker, it is turned into a normal marker.
Suffix:
<n>
.
Window
<m> Marker
Parameters:
<State> ON | OFF | 0 | 1
OFF | 0
Switches the function off
ON | 1
Switches the function on
Analyzing Measurements (Basics)