Remote Commands
R&S
®
FSW
1324User Manual 1173.9411.02 ─ 43
BIDir
Changes of a parameter are applied both ways (from channel 1
to channel 2 and vice versa).
LTOR
Changes of a parameter are applied from channel 1 to channel
2, but not the other way around.
RTOL
Changes of a parameter are applied from channel 2 to channel
1, but not the other way around.
Example:
INST:COUP:USER:REL BID
Selects bidirectional changes for the user-defined coupling with
the index number 1.
Manual operation: See "Direction" on page 724
INSTrument:COUPle:USER<uc>:REMove
[<Scope>]
This command deletes a user-defined coupling mechanism.
Suffix:
<uc>
.
Index of a user-defined parameter coupling. Which indexes are
available is defined by INSTrument:COUPle:USER<uc>:
NUMBers:LIST?.
Parameters:
<Scope> ALL
Optional SCPI parameter, used instead of the <uc> suffix.
Deletes all user-defined couplings.
Example:
INST:COUP:USER3:REM
Removes the user-defined coupling with the index number 3.
Manual operation: See "Delete coupling definition" on page 724
See "Delete All" on page 724
INSTrument:COUPle:USER<uc>:STATe <State>
Enables or disables the specified user-defined parameter coupling.
Suffix:
<uc>
.
Index of a user-defined parameter coupling. Which indexes are
available is defined by INSTrument:COUPle:USER<uc>:
NUMBers:LIST?.
Parameters:
<State> ON | OFF | 1 | 0
OFF | 0
Switches the function off
ON | 1
Switches the function on
*RST: 0
Configuring the R&S FSW

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the R&S FSW Series and is the answer not in the manual?

R&S FSW Series Specifications

General IconGeneral
BrandR&S
ModelFSW Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals