General Instrument Setup
R&S
®
FSW
686User Manual 1173.9411.02 ─ 43
4. Edit the line configuration as described in "How to configure a new transducer line"
on page 686.
5. Save the new configuration by selecting the "Save" button.
The new transducer line is displayed in the overview and can be activated.
How to delete an existing transducer line
1. In the "Transducer" dialog box, select the transducer line.
2. Select the "Delete" button.
3. Confirm the message.
The transducer line is deleted. After the next sweep, the originally measured val-
ues are displayed.
How to configure a new transducer line
1. In the "Transducer" dialog box, select the "New" button.
The "Edit Transducer" dialog box is displayed. The current line configuration is dis-
played in the preview area of the dialog box. The preview is updated after each
change to the configuration.
2. Define a "Name" and, optionally, a "Comment" for the new transducer line.
3. Define the scaling for the x-axis.
4. Define the data points: minimum 2, maximum 1001:
a) Select "Insert Value".
b) Define the x-value ("Position") and y-value ("Value") of the first data point.
c) Select "Insert Value" again and define the second data point.
d) Repeat this to insert all other data points.
To insert a data point before an existing one, select the data point and then
"Insert Value".
To insert a new data point at the end of the list, move the focus to the line after
the last entry and then select "Insert Value".
To delete a data point, select the entry and then "Delete Value".
5. Check the current line configuration in the preview area of the dialog box. If neces-
sary, correct individual data points or add or delete some.
If necessary, shift the entire line vertically or horizontally by selecting the "Shift x" or
"Shift y" button and defining the shift width.
6. Save the new configuration by selecting the "Save" button.
The new transducer line is displayed in the overview and can be activated.
Transducers

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the R&S FSW Series and is the answer not in the manual?

R&S FSW Series Specifications

General IconGeneral
BrandR&S
ModelFSW Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals