910User Manual 1173.9411.02 ─ 43
ERRor
Control error, for example because a specified value cannot be
applied on the signal generator
Example:
CONF:GEN:NPR:NOTC1:STAT?
Usage: Query only
Manual operation: See "Notch Bandwidth (Absolute / Relative to Channel BW)"
on page 225
CONFigure:GENerator:NPRatio:NOTCh<notch>:FREQuency:OFFSet:CSTate?
Queries the state of the frequency offset for the specified notch.
Suffix:
<notch>
.
1..n
Return values:
<ControlState> OFF | SUCCessful | ERRor
OFF
Signal generator control off
SUCCessful
Setting successfully applied on the signal generator
ERRor
Control error, for example because a specified value cannot be
applied on the signal generator
Example:
CONF:GEN:NPR:NOTC1:FREQ:OFFS:CST?
Usage: Query only
Manual operation: See "Frequency Offset per Notch" on page 225
CONFigure:GENerator:NPRatio:NOTCh<notch>:STATe:CSTate?
Queries the state of the generator notch setting for the specified notch.
Suffix:
<notch>
.
1..n
Return values:
<ControlState> OFF | SUCCessful | ERRor
OFF
Signal generator control off
SUCCessful
Setting successfully applied on the signal generator
ERRor
Control error, for example because a specified value cannot be
applied on the signal generator
Example:
CONF:GEN:NPR:NOTC:STAT:CST?
Usage: Query only