Remote Commands
R&S
®
FSW
932User Manual 1173.9411.02 ─ 43
OFF
No function is used, the relative limit line is defined by a fixed
relative stop value. Use the [SENSe:]ESPectrum<sb>:
RANGe<ri>:LIMit<li>:RELative:STOP command to define
this value.
*RST: OFF
Example:
SENSe:ESPectrum:RANGe:LIMit:RELative:STOP:
FUNCtion MAX
For a detailed example see Chapter 14.5.7.11, "Example: SEM
Measurement", on page 950.
Manual operation: See "Rel Limit Start / Stop <n>" on page 254
[SENSe:]ESPectrum<sb>:RANGe<ri>:LIMit<li>:STATe <State>
This command selects the limit check mode for all SEM ranges (<range> is irrelevant).
Suffix:
<sb>
.
1 to 8
Sub block in a Multi-SEM measurement
<ri> 1..n
Selects the SEM range.
<li> 1..n
Power class for which the limit is defined.
Parameters:
<State> ABSolute | RELative | AND | OR
ABSolute
Checks only the absolute limits defined.
RELative
Checks only the relative limits. Relative limits are defined as rel-
ative to the measured power in the reference range.
AND
Combines the absolute and relative limit. The limit check fails
when both limits are violated.
OR
Combines the absolute and relative limit. The limit check fails
when one of the limits is violated.
*RST:
RELative
Manual operation: See "Limit Check <n>" on page 254
[SENSe:]ESPectrum<sb>:RANGe<ri>:POINts:MINinum[:VALue] <SweepPoint>
Defines the minimum number of sweep points for the range.
Suffix:
<sb>
.
1 to 8
Sub block in a Multi-SEM measurement
Configuring and Performing Measurements