R&S
®
ZVA / R&S
®
ZVB / R&S
®
ZVT GUI Reference
Channel Menu
Operating Manual 1145.1084.12 – 30 262
for selected segments.
If Trig is unchecked for a particular segment, all triggers within this segment are inactive: it will be
sweeped in one go, immediately after the previous one.
The configured Trig states are preserved while the Trigger flag is inactive (and the column is
hidden). However, they only take effect while the Trigger flag is active and if
1. the analyzer is not in Free Run mode
2. the Triggered Measurement Sequence is different from Sweep
Time
defines the sweep time for each segment. The default configuration for a new segment is equal to
the Sweep Time settings.
When Time is checked two new columns appear in the table. The first column reads Swp Tm or
Meas Dly, depending on the selected radio button below the Time checkbox. The second column
reads A(uto) and is used to activate automatic sweep time setting.
A(uto) minimizes the sweep time. If this option is checked, the columns Swp Tm or Meas.
Dly can not be edited. Swp Tm indicates the estimated sweep time, taking into account
the current measurement settings, the Meas. Dly is 0 s. The segment sweep time and
point delay values are maintained until changed explicitly if Auto is switched off.
Sweep Time or Segment Sweep Time is the total measurement time for the sweep
segment. The minimum segment sweep time to be set is equal to the estimated value in
the Auto mode.
Meas Delay sets a delay time allowing the DUT to settle before the hardware settings of
the analyzer are changed and a new partial measurement is started
Changing the Meas. Delay modifies the Sweep Time and vice versa.
[SENSe<Chn>:]SEGMent<Seg>:INSert
[SENSe<Chn>:]SEGMent<Seg>:DEFine
[SENSe<Chn>:]SEGMent<Seg>:NAME
[SENSe<Chn>:]SEGMent<Seg>:POWer[:LEVel]
[SENSe<Chn>:]SEGMent<Seg>:BWIDth[RESolution]
[SENSe<Chn>:]SEGMent<Seg>:BWIDth[RESolution]:SELect
[SENSe<Chn>:]SEGMent<Seg>:SBANd
[SENSe<Chn>:]SEGMent<Seg>:SBANd:CONTrol
OUTPut<Ch>:UPORt:SEGMent<Seg>:STATe
OUTPut<Ch>:UPORt:SEGMent<Seg>[:VALue]
[SENSe<Ch>:]SEGMent<Seg>:TRIGger:CONTrol
[SENSe<Ch>:]SEGMent<Seg>:TRIGger:STATe
[SENSe<Chn>:]SEGMent<Seg>:SWEep:TIME
[SENSe<Chn>:]SEGMent<Seg>:SWEep:DWELl
Point List, Segment Import and Export
The buttons on the right side below the table in the Define Segments dialog are used to retrieve
the position of the defined sweep points import and export limit line data.
Show Point List
opens a list of all active sweep points and their channel settings.