EasyManua.ls Logo

Ruijie RG-S2600G-I Series - Page 1122

Ruijie RG-S2600G-I Series
1192 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CLI Reference VSU Configuration Commands
VSU Configuration Commands
dual-active detection
Configure dual-active detection function. The no form of this command is used to restore the default
configuration.
dual-active detection { aggregateport | bfd }
no dual-active detection { aggregateport | bfd }
Parameter
Description
Parameter
Description
aggregateport
Specify the aggregate port detection mode.
bfd
Specify the Bidirectional Forwarding Direction (BFD) mode.
Default
Configuration
The dual-active detection is disabled by default.
Command
Mode
config-vs-domain configuration mode
Usage
Guidelines
This command can only be executed in VSU mode.
Configuration
Examples
Example 1 enables BFD dual-active detection.
Ruijie(config)# switch virtual domain
1
Ruijie(config-vs-domain)# dual-active detection bfd
Example 2 disables BFD dual-active detection.
Ruijie(config)# switch virtual domain
1
Ruijie(config-vs-domain)# no dual-active detection bfd
Example 3 enables aggregate port dual-active detection.
Ruijie(config)# switch virtual domain
1
Ruijie(config-vs-domain)# dual-active detection aggregateport
Example 4 disables aggregate port dual-active detection.
Ruijie(config)# switch virtual domain
1
Ruijie(config-vs-domain)# no dual-active detection aggregateport
Related
Commands
Command
Description
dual-active interface
Configure AP-based dual-active detection
interfaces.

Table of Contents