CLI Reference VSU Configuration Commands
dual-active bfd interface
Configure BFD dual-active detection interfaces.
dual-active exclude interface
Configure the exclude interface of dual-active
detection.
show switch virtual dual-active
Check the configuration and status of the
dual-active detection function.
Platform
Description
N/A
dual-active exclude interface
Configure the exclude interface of VSU in the recovery mode. The no form of this command is used
to cancel the exclude interface.
dual-active exclude interface interface-name
no dual-active exclude interface interface-name
Parameter
Description
Parameter
Description
interface-name
Indicates the interface type and number
Default
Configuration
N/A
Command
Mode
config-vs-domain configuration mode
Usage
Guidelines
This command can only be executed in the VSU mode.
The exclude interface must be a routing interface but not a VSL interface.
Users can configure multiple exclude interfaces.
Configuration
Examples
The following example configures Gi 1/0/3 as the exclude interface of dual-active detection.
Ruijie(config)# interface GigabitEthernet 1/0/3
Ruijie(config-if)# no switchport
Ruijie(config)# switch virtual domain 1
Ruijie(config-vs-domain)# dual-active exclude interface GigabitEthernet 1/0/3
Related
Commands
Command
Description
dual-active detection
Configure the functional switch of dual-active
detection.
dual-active bdf interface
Configure the interface of BFD dual-active detection
to detect the dual-active device status.
dual-active interface
Configure the interface of aggregate port dual-active
detection to detect the dual-active device status.

Table of Contents

Related product manuals