CLI Reference VSU Configuration Commands
show switch virtual dual-active
Check the configuration and status of the dual-active
detection function.
dual-active bfd interface
Configure the bfd detection interface. The no form of this command is used to cancel the detection
interface.
dual-active interface interface-name
no dual-active bfd interface interface-name
Indicates the interface type and number
config-vs-domain configuration mode
The BFD detection interfaces must be routed ports on different devices.
The following example configures Gi1/1/1 port as the BFD dual-active detection interface.
Ruijie(config)# interface GigabitEthernet 1/1/1
Ruijie(config-if)# no switchport
Ruijie(config)# switch virtual domain 1
Ruijie(config-vs-domain)# dual-active bfd interface GigabitEthernet 1/1/1
Configure the functional switch of dual-active
detection.
show switch virtual dual-active
Check the configuration and status of the
dual-active detection function.