CLI Reference VSU Configuration Commands
dual-active interface
Use this command to configure AP-based dual-active detection interfaces. Use the no form of this
command is used to delete the detection interfaces.
dual-active interface interface-name
no dual-active interface
Parameter
Description
Parameter
Description
interface-name
Indicates the type and number of detection interface. The interface
must be an AP type.
Default
Configuration
N/A
Command
Mode
config-vs-domain configuration mode
Usage
Guidelines
You can configure only one AP-based dual-active detection interface. Before setting the AP port as
the detection interface, create the interface. The latter configured detection interface will cover the
formerly configured one.
Configuration
Examples
The following example configures aggregate port 1 as a detection interface.
Ruijie(config)# interface aggregateport 1
Ruijie(config-if-AggregatePort 1)#exit
Ruijie(config)# switch virtual domain 1
Ruijie(config-vs-domain)# dual-active interface aggregateport 1
Related
Commands
Command
Description
dual-active detection
Configure the functional switch of dual-active
detection.
show switch virtual dual-active
Check the configuration and status of the
dual-active detection function.
Platform
Description
N/A
dad relay enable
Use this command to configure AP-based detection dual-active forwarding function. Use the no form
of this command to disable the forwarding function.
dad relay enable
no dad relay enable