CLI Reference NFPP Configuration Commands
guidelines
0, the attacker will be monitored by the software and
the timeout time will be the monitor period. During the
software monitoring, if the isolate period is not 0, the
software-monitored attacker will be auto-isolated by
the hardware and the timeout time will be the isolate
period. The monitor period is valid with the isolate
period 0.
If the isolate period has changed to be 0, the
attackers on the interface will be removed rather than
being monitored by the software.
Examples
Ruijie(config)# nfpp
Ruijie(config-nfpp)# nfpp define tcp
Ruijie(config-nfpp-define)#monitor-period 1000
Related
commands
Command
Description
show nfpp define
summary
Show the user-defined
anti-attack configurations
nfpp define
Use this command to create the user-defined anti-attack type.
nfpp define name
Parameter
description
Parameter
Description
name
Name of the user-defined
anti-attack type.
Default
Settings
N/A
Command
mode
NFPP configuration mode.
Usage
guidelines
Use this command to create a new user-defined
anti-attack type.
Examples
Ruijie(config)# nfpp
Ruijie(config-nfpp)# nfpp define tcp
Ruijie(config-nfpp-define)#