166
<CC>0
<V>100<H>200<K1>H9021
<Q>2
<Z>
[Coding Example 2]
Registration data in Shift JIS binary code.
<A>
<KS>0
<KC>1
<CC>0
<T1>B<40>
16
<00FF..........FF00>
16
<Z>
  
<A>
<KS>0
<KC>1
<CC>0
<V>100<H>200<K1>B<90>
16
<40>
16
<Q>2
<Z>
[Coding Example 3]
Registration data in Unicode binary code.
<A>
<KS>0
<KC>2
<CC>0
<T1>B<00>
16
<00FF..........FF00>
16
<Z>
  
<A>
<KS>0
<KC>2
<CC>0
<V>100<H>200<K1>B<E0>
16
<00>
16
<Q>2
<Z>
[Coding Example 4]
Register in the user registration memory.
<A>
<KS>0
<KC>1
<CC>1
<T1>B<40>
16
<00FF..........FF00>
16
<Z>