245
[Format] (version)
<QV>pp : Specify when specifying the version.
• Parameter
pp [Version] = 00 to 04 (MicroQR M1 to M4)
   
* This setting is used when fixing the size of QR symbol with the version command.
When not specified, it becomes Auto.
   
Specifying 00 also becomes Auto. It does not become a parameter error from 00 to 40.
   
* See [QR code version command] for details.
[Supplementary Explanation1]
• When specifying Kanji in <DN>, specify size that is 2 x number of Kanji characters.
• For <DN> in Automatic setup, when 80H to 9FH and E0H to FFH is specified as data, it is
handed as Kanji mode, and cannot specify them as binary.
[Coding Example1]
Error correction level :7%, Size of one side of cell:04
<A>
<V>100<H>200<2D32>,L,04,0
<DS>1,012345
<Q>2
<Z>
[Supplementary Explanation2]
• If the parameter other than the description is specified or number of print data does not match,
printing is not performed.
• Data specification command in data part varies according to parameter setup or specified data.
[Coding Example2]
Error correction level: 7%, Size of one side of cell: 04
Mixed specification of Manual setup (Data setup mode)
In Manual setup, you can proceed specifying data in specified input mode (Numeric, Alphanumeric,
Kanji, Binary) in a row.
<A>
<V>100<H>200
<2D32>,L,04,0
<DS>3,SATO
<DN>0010,0123456789
<DS>1,123
<Q>1
<Z>