388
[Supplementary Explanation]
Specify the card slot number used for Card Slot <CC> prior to this command.
Specify registered data only.
To change the registered content, clear it with Clear <*> to re-register.
Graphic Call <GR> is for printing out the data registered with Registration of Graphic <GI>.
When data is not registered properly, print error may occur.
For details of data format, refer to Print of Graphic <G>.
The error occurs when specifying unused or specifying the slot which this product is allocated.
[Note]
Do not turn the printer's power off when accessing to the memory. When the printer power is off
while memory accessing, the data in the accessed media may be corrupted.
[Specified Range]
Model Head density Maximum byte in
horizontal direction
Maximum byte in
vertical direction
203 dpi 104 400
305 dpi 156 600
CL4NX
609 dpi 312 999
203 dpi
152
*1
167
*2
400CL6NX
305 dpi
248
*1
251
*2
600
*1 Valid range when “Head Base Position” is set to “Standard”.
*2 Valid range when “Head Base Position” is set to “Left-justify”.