454
Data input format + number of data to write in bytes
"D" or "d" shows that this field is
for specifying the number of data
to write.
Capital "D" indicates that the
data is in ASCII, lower-case "d"
indicates the write data is in HEX.
Specify the length of data in bytes
with the number(mmmm) that
comes after "D" or "d".
in bytes, so the number specified for this field will not
change regardless of data format, whether ASCII or
HEX.
Specify 0 if there is no data to write to user memory,
in which case specify nothing but the comma for the
succeeding “n: data array to write”.
Data array to write
This parameter is used when the user data is set by using
free format or when there is no user data.
The character code and maximum number of characters
varies depending on the data input/output format (ASCII/
HEX) as below:
ASCII Range of available character codes :(00H) -
(FFH)
See “Mapping table of IC chip type, number
of blocks and total capacity” for the valid
number of characters. It can be specified
by unit of 1 character, so it is the same as
maximum number of bytes allowed for each
IC chip.
n Data array to write
HEX Range of available character codes : 0(30H)
~ 9(39H),A(41H) ~ F(46H)
Specify digits with multiples of 2. The
number of valid characters would be twice
the number of characters available for the
maximum number of bytes for each IC chip,
mentioned in "Mapping table of IC chip type,
number of blocks and total capacity".
Specifying NFC(NDEF) format
NFC: Specify this parameter when you set data in NDEF(NFC Data Exchange Format)
format stipulated by NFC forum.
Valid
range:
1 ~ 6,f
[When setting NFC(NDEF) format user data]
1: user data is regarded as URI format.
2: user data is regarded as TEXT format.
3: user data is regarded as smart poster format.
4: user data is regarded as handover (Bluetooth) format.
5: user data is regarded as handover (Wi-Fi) format.
6: user data is regarded as handover (mixture of Bluetooth/Wi-Fi) format.
[When setting free format user data]
f: User data is written as a free format NDEF message.
* Of a case and the user data that user data is not NDEF form when there is not it, this
designation is unnecessary.

Table of Contents

Other manuals for SATO CL6NX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SATO CL6NX and is the answer not in the manual?

SATO CL6NX Specifications

General IconGeneral
Flash memory2000 MB
Storage mediaFlash
Internal memory256 MB
Built-in barcodesCode 39, Code 93, Code-128 Codabar Library, EAN13, EAN8, GS1 DataBar, Industrial 2/5, Interleaved 2/5, Matrix 2/5
Internal storage capacity2 GB
Cables includedAC
Maximum roll diameter220 mm
Maximum printing width167.5 mm
Printing media thickness0.08 - 0.268 µm
USB portYes
USB connectorUSB Type-A / USB Type-B
Bluetooth version3.0
Serial interface typeRS-232C
USB 2.0 ports quantity2
Connectivity technologyWired & Wireless
Wi-FiNo
Display typeLCD
Product colorBlack
Display diagonal3.5 \
Display resolution320 x 240 pixels
AC input voltage100 - 240 V
AC input frequency50 - 60 Hz
Storage temperature (T-T)-20 - 60 °C
Operating temperature (T-T)0 - 40 °C
Storage relative humidity (H-H)30 - 90 %
Operating relative humidity (H-H)30 - 80 %
TypePOS printer
Print speed10 ips
Print technologyDirect thermal / Thermal transfer
Maximum resolution203 x 203 DPI
Weight and Dimensions IconWeight and Dimensions
Depth457 mm
Width338 mm
Height321 mm
Weight20000 g