483
This command cannot be specified multiple times in between <A>(start of data transmission)
through <Z>(end of data transmission).
Contents of sequential printing or calendar cannot be written as information to the tag.
The sent information and written information are verified before printing when information is
written to tag with this command.
The default value of parameter b is 0 (stop without ignoring tag error).
If printing object doesn’t exist for the print job that includes this command, printer only writes for
RFID and doesn’t feed label. The buzzer will sound 6 times if it fails to write to tag. If successful,
the buzzer is sounded 2 times but does not feed the label. If you want to feed or print as blank
label specify 1 for the “fsw: feed without printing” field.
Refer to the following chart if you want to specify the alphabet “A” in ASCII/HEX data formats.
Mode ASCII HEX
Data 'A' "41"
Code 41H 34H,31H
Parent topic RFID Command (CL4NX Only)