561
[Exception processing]
Exception conditionParameter name
A value outside the
range is specified
The specified size and
received size are different
Identifier Command error Invalid receive data
Terminology Description
Command error The data received after a command error is determined is not considered as a
parameter of this command.
Invalid receive data The data corresponding to Byte 2 and thereafter of the identifier is ignored.
[Supplemental explanation]
• Setting value of the printer will be switched when switching the application. So, obtaining and
saving the setting of the application before switching, then switching it, and then put it back
to the original application, after that set it by previously saved settings, and it performs the
operation before switching it.
e.g.) When switching the application such as SBPL -> STCL -> SBPL
1. Obtain and save the setting value of SBPL state (obtain the setting value by AIOT,
[DC2]PB[EOT] and so on).
2. Switch the application to STCL.
3. Switch the application to SBPL.
4. Set the setting value obtained and saved in the step 1).
• Please send this command in a state which the printer is not working anything in Offline or
Online standby state waiting state.
The result of this command sent in pause status during cancellation is not guaranteed. In such
case, restart the printer.
• AUTO mode will not be available unless you reboot after switching to AUTO mode. The printer
works with the application before the change until it reboots.
DC2+PI,aa
ACK/NAK (when a command error occurs)
This product
Host
Parent topic Common commands for all languages