EasyManua.ls Logo

SATO CL6NX - Page 603

SATO CL6NX
756 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
601
Symbol Parameter name Valid range Acquisition method
d File size 0 to 999999999 (byte) Acquired up to ","
e File data - Equivalent to file size
[Return data format (normal)]
[ACK]<06>
16
[Return data format (when a command error occurs)]
[NAK]<15>
16
[Return data format (when the same file name error occurs)]
1<31>
16
[Exception processing]
Exception conditionParameter name
A value outside the
range is specified
The specified
size and received
size are different
When the same file name
Identifier Command error Command error -
File type Command error Command error -
File name Command error - Same file name error
File size Command error - -
File data - Invalid receive data -
Terminology Description
Command error Downloading not performed. The data received after a command error is
determined is not considered as a parameter of this command.
Same file name error The file is not saved.
Invalid receive data The data exceeding the file size is ignored.
[Supplemental explanation]
• Send this command when printing has stopped. The content of the response data is not
guaranteed even when this command is received during printing.
• When you specify SZPL for "Parameter a: Identifier ", "0: Font/logo", "1: TrueType font" settings
of "Parameter b: File type" will be ignored.
  

Table of Contents