711
Disconnection timeout period (SPP layer)
0 second (Initial value)
Disconnection timeout period (LMP layer)
60 seconds (Initial value)
Parameter
Setting item Setting range
Protocol Status 3
Status 4 (Initial value)
None
Receive buffer size
2.95 MB
Near Full
Release Near
Full
0 MB
2.95 MB
Remaining 0.95 MB
Remaining 1.95 MB
Pairing
Keep link keys for 10 devices
CoD (Class of Device)
Major service class: Unspecified
Major device class: Imaging major class
Minor device class: Printer
supervision timeout
Initial value=20 seconds (Changeable from host)
[Supplementary Explanation]
• Printer operates in slave mode. Before establishing connection, specify Bluetooth Device
address (BD address) from the master.
• Connection may not be established when master’s authentication mode, packet type, and PIN
code are different from above setting. In that case, confirm authentication level and PIN code by
[Settings] menu > [Tools] menu > [Test Print] > [Configure List], match with master setting and
try reconnection.
• Bluetooth interface and printer is connected by internal serial interface , and transfer speed is
115200bps.
• When Bluetooth LINK is lost (e.g. out of service area), disconnects from the printer after
supervision timeout period has passed.
• When Bluetooth communication is disconnected while sending print data (STX<A> to <Z>ETX),
the received data is discarded after disconnection time-out period has passed. It is required
to resend print data (STX<A> to <Z>ETX) when time out occurs. Time out is not monitored if
disconnection time out period is set to 0.