Parameter Description Issue 01/06
MICROMASTER 440 Parameter List
126 6SE6400-5BB00-0BP0
P1076[3] CI: Additional setpoint scaling Min: 0:0
CStat: CT Datatype: U32 Unit: - Def: 1:0
P-Group: SETPOINT Active: first confirm QuickComm.: No Max: 4000:0
Defines source of scaling for additional setpoint (to be added to main setpoint).
Index:
P1076[0] : 1st. Command data set (CDS)
P1076[1] : 2nd. Command data set (CDS)
P1076[2] : 3rd. Command data set (CDS)
Common Settings:
1 = Scaling of 1.0 (100%)
755 = Analog input 1 Setpoint
1024 = Fixed Frequency Setpoint
1050 = MOP Setpoint
r1078 CO: Total frequency setpoint Min: -
Datatype: Float Unit: Hz Def: -
P-Group: SETPOINT Max: -
Displays sum of main and additional setpoints in [Hz].
r1079 CO: Selected frequency setpoint Min: -
Datatype: Float Unit: Hz Def: -
P-Group: SETPOINT Max: -
Displays selected frequency setpoint.
Following frequency setpoints are displayed:
- r1078 Total frequency setpoint
- P1058 JOG frequency right
- P1059 JOG frequency left
Dependency:
P1055 (BI: Enable JOG right) or P1056 (BI: Enable JOG left) define command source of JOG right or JOG
left respectively.
Note:
P1055 = 0 and P1056 = 0 ==> Total frequency setpoint is selected.
Level
3
Level
3
Level
3