Parameter Description Issue 01/06
MICROMASTER 440 Parameter List
240 6SE6400-5BB00-0BP0
P2484[3] No. of shaft turns = 1 Unit Min: 0.01
CStat: CUT Datatype: Float Unit: - Def: 1.00
P-Group: CONTROL Active: first confirm QuickComm.: No Max: 9999.99
Sets the number of rotations of the motor shaft required to represent 1 unit of user selected units.
==
s
U
P2484
Load
M
o
t
o
r
Pulley radius r
No. of revolutions
1 [unit]
U
Distance s
The following equation determines the number of motor shaft revolutions to stop:
2482P
2481P
2484P2488P â‹…â‹…=
Revolutions
Motor
Index:
P2484[0] : 1st. Drive data set (DDS)
P2484[1] : 2nd. Drive data set (DDS)
P2484[2] : 3rd. Drive data set (DDS)
P2488[3] Distance / No. of revolutions Min: 0.01
CStat: CUT Datatype: Float Unit: - Def: 1.00
P-Group: CONTROL Active: first confirm QuickComm.: No Max: 9999.99
Sets the required distance or number of revolutions (see P2484).
Motor Gear
f
â‹…==
2
1
P2488 s
t
OFF1
f
OFF 1
.
t
P2488
.
t
P2488
f
OFF 1
Index:
P2488[0] : 1st. Drive data set (DDS)
P2488[1] : 2nd. Drive data set (DDS)
P2488[2] : 3rd. Drive data set (DDS)
r2489 Act. number of shaft revolutions Min: -
Datatype: Float Unit: - Def: -
P-Group: CONTROL Max: -
Displayes the actual number of shaft revolutions since trigger of positioning.
Note:
Positioning ramp down is an open loop control method. So, there might be a difference between the position
setpoint and the calculated actual position shown in r2489. That means, it could happen that the setpoint
position is already reached, although r2489 displays a different actual position .