EasyManua.ls Logo

Siemens MICROMASTER 440 - Flux Setpoint (SLVC and VC) Diagram

Siemens MICROMASTER 440
328 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Issue 01/06 Function Diagrams
MICROMASTER 440 Parameter List
6SE6400-5BB00-0BP0
303
Current control
and stall
protection
Saturation characteristic
P0362 ... P0369 *)
Speed control
Field weakening controller
Efficiency optimization
Field weakening
characteristic
Act. frequency
Current control
Vdc measurement
- 7800 -
Function diagram
87654321
7800_VC.vsd
Vector Control
MICROMASTER 440
16.01.2006 V2.1
Flux Setpoint (SLVC and VC)
Max. modulation
20.0 ... 150.0 [%]
P1803.D (106.0)
Dyn. volt headroom
0 ... 150 [V]
P1574.D (10)
*) Access level 4
*)
r0071
CO: Max. outp.volt [V]
Vsetp.
Int.time weak.ctrl
20 ... 32001 [ms]
P1596.D (50)
CO/BO:Stat MotCtrl
r0056
r0056
0
r1597
CO:Outp.weak. ctrl [%]
*)
CO: Fval flux setp
50.0 ... 200.0 [%]
P1570.D (107.0)
Acc trq boost SLVC
0.0 ... 200.0 [%]
P1611.D (0.0)
CO/BO:Stat MotCtrl
r0056
r0056
MIN
1
Magnetization time
0.000 ... 20.000 [s]
P0346.D (1.000)
Flux setp. Tsmooth
4 ... 500 [ms]
P1582.D (15)
CO/BO:Stat MotCtrl
r0056
r0056
1
0
r1583
CO: Smoothed setp. [%]
r1598
CO:Total flux setp [%]
Cont. torque boost
0.0 ... 200.0 [%]
P1610.D (50.0)
30 ms
Flux
setpoint
generation
Id
*)
−
−
r1508
CO: Torque setp. [Nm]
r0026
CO: Act. fil. Vdc [V]
Rotor time const. [ms]
r0384.D
Rated magnet. cur. [A]
r0331.D
Efficiency optimiz
0 ... 100 [%]
P1580.D (0)
Motor model StatWd
r1751
:
x -y
22
2
www . ElectricalPartManuals . com

Table of Contents

Other manuals for Siemens MICROMASTER 440

Related product manuals