Issue 01/06 Parameter Description
MICROMASTER 440 Parameter List
6SE6400-5BB00-0BP0
251
P2851 Mode timer 1 Min: 0
CStat: CUT Datatype: U16 Unit: - Def: 0
P-Group: TECH Active: first confirm QuickComm.: No Max: 13
Selects mode of timer 1. P2849, P2850, P2851 are the inputs of the timer, outputs are P2852, P2853.
Possible Settings:
0 ON delay (seconds)
1 OFF delay (seconds)
2 ON/OFF delay (seconds)
3 Pulse generator (seconds)
10 ON delay (minutes)
11 OFF delay (minutes)
12 ON/OFF delay (minutes)
13 Pulse generator (minutes)
Dependency:
P2802[0] is active level for the timer.
r2852 BO: Timer 1 Min: -
Datatype: U16 Unit: - Def: -
P-Group: TECH Max: -
Displays output of timer 1. P2849, P2850, P2851 are the inputs of the timer, outputs are P2852, P2853.
Dependency:
P2802[0] is active level for the timer.
r2853 BO: Nout timer 1 Min: -
Datatype: U16 Unit: - Def: -
P-Group: TECH Max: -
Displays Not-output of timer 1. P2849, P2850, P2851 are the inputs of the timer, outputs are P2852, P2853.
Dependency:
P2802[0] is active level for the timer.
P2854 BI: Timer 2 Min: 0:0
CStat: CUT Datatype: U32 Unit: - Def: 0:0
P-Group: TECH Active: first confirm QuickComm.: No Max: 4000:0
Define input signal of timer 2. P2854, P2855, P2856 are the inputs of the timer, outputs are P2857, P2858.
Dependency:
P2802[1] is active level for the timer.
P2855 Delay time of timer 2 Min: 0.0
CStat: CUT Datatype: Float Unit: - Def: 0.0
P-Group: TECH Active: first confirm QuickComm.: No Max: 9999.9
Defines delay time of timer 2. P2854, P2855, P2856 are the inputs of the timer, outputs are P2857, P2858.
Dependency:
P2802[1] is active level for the timer.
P2856 Mode timer 2 Min: 0
CStat: CUT Datatype: U16 Unit: - Def: 0
P-Group: TECH Active: first confirm QuickComm.: No Max: 13
Selects mode of timer 2. P2854, P2855, P2856 are the inputs of the timer, outputs are P2857, P2858.
Possible Settings:
0 ON delay (seconds)
1 OFF delay (seconds)
2 ON/OFF delay (seconds)
3 Pulse generator (seconds)
10 ON delay (minutes)
11 OFF delay (minutes)
12 ON/OFF delay (minutes)
13 Pulse generator (minutes)
Dependency:
P2802[1] is active level for the timer.
r2857 BO: Timer 2 Min: -
Datatype: U16 Unit: - Def: -
P-Group: TECH Max: -
Displays output of timer 2. P2854, P2855, P2856 are the inputs of the timer, outputs are P2857, P2858.
Dependency:
P2802[1] is active level for the timer.