EasyManua.ls Logo

Siemens MICROMASTER 440 - Programmable V;F Volt. Coord. 1; Programmable V;F Freq. Coord. 2; Programmable V;F Volt. Coord. 2; Programmable V;F Freq. Coord. 3

Siemens MICROMASTER 440
328 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Description Issue 01/06
MICROMASTER 440 Parameter List
160 6SE6400-5BB00-0BP0
P1321[3] Programmable V/f volt. coord. 1 Min: 0.0
CStat: CUT Datatype: Float Unit: V Def: 0.0
P-Group: CONTROL Active: Immediately QuickComm.: No Max: 3000.0
See P1320 (programmable V/f freq. coord. 1).
Index:
P1321[0] : 1st. Drive data set (DDS)
P1321[1] : 2nd. Drive data set (DDS)
P1321[2] : 3rd. Drive data set (DDS)
P1322[3] Programmable V/f freq. coord. 2 Min: 0.00
CStat: CT Datatype: Float Unit: Hz Def: 0.00
P-Group: CONTROL Active: Immediately QuickComm.: No Max: 650.00
See P1320 (programmable V/f freq. coord. 1).
Index:
P1322[0] : 1st. Drive data set (DDS)
P1322[1] : 2nd. Drive data set (DDS)
P1322[2] : 3rd. Drive data set (DDS)
P1323[3] Programmable V/f volt. coord. 2 Min: 0.0
CStat: CUT Datatype: Float Unit: V Def: 0.0
P-Group: CONTROL Active: Immediately QuickComm.: No Max: 3000.0
See P1320 (programmable V/f freq. coord. 1).
Index:
P1323[0] : 1st. Drive data set (DDS)
P1323[1] : 2nd. Drive data set (DDS)
P1323[2] : 3rd. Drive data set (DDS)
P1324[3] Programmable V/f freq. coord. 3 Min: 0.00
CStat: CT Datatype: Float Unit: Hz Def: 0.00
P-Group: CONTROL Active: Immediately QuickComm.: No Max: 650.00
See P1320 (programmable V/f freq. coord. 1).
Index:
P1324[0] : 1st. Drive data set (DDS)
P1324[1] : 2nd. Drive data set (DDS)
P1324[2] : 3rd. Drive data set (DDS)
P1325[3] Programmable V/f volt. coord. 3 Min: 0.0
CStat: CUT Datatype: Float Unit: V Def: 0.0
P-Group: CONTROL Active: Immediately QuickComm.: No Max: 3000.0
See P1320 (programmable V/f freq. coord. 1).
Index:
P1325[0] : 1st. Drive data set (DDS)
P1325[1] : 2nd. Drive data set (DDS)
P1325[2] : 3rd. Drive data set (DDS)
P1330[3] CI: Voltage setpoint Min: 0:0
CStat: T Datatype: U32 Unit: - Def: 0:0
P-Group: CONTROL Active: first confirm QuickComm.: No Max: 4000:0
BICO parameter for selecting source of voltage setpoint for independent V/f control.
Index:
P1330[0] : 1st. Command data set (CDS)
P1330[1] : 2nd. Command data set (CDS)
P1330[2] : 3rd. Command data set (CDS)
Level
3
Level
3
Level
3
Level
3
Level
3