Parameter Description Issue 01/06
MICROMASTER 440 Parameter List
252 6SE6400-5BB00-0BP0
r2858 BO: Nout timer 2 Min: -
Datatype: U16 Unit: - Def: -
P-Group: TECH Max: -
Displays Not-output of timer 2 P2854, P2855, P2856 are the inputs of the timer, outputs are P2857, P2858.
Dependency:
P2802[1] is active level for the timer.
P2859 BI: Timer 3 Min: 0:0
CStat: CUT Datatype: U32 Unit: - Def: 0:0
P-Group: TECH Active: first confirm QuickComm.: No Max: 4000:0
Define input signal of timer 3. P2859, P2860, P2861 are the inputs of the timer, outputs are P2862, P2863.
Dependency:
P2802[2] is active level for the timer.
P2860 Delay time of timer 3 Min: 0.0
CStat: CUT Datatype: Float Unit: - Def: 0.0
P-Group: TECH Active: first confirm QuickComm.: No Max: 9999.9
Defines delay time of timer 3. P2859, P2860, P2861 are the inputs of the timer, outputs are P2862, P2863.
Dependency:
P2802[2] is active level for the timer.
P2861 Mode timer 3 Min: 0
CStat: CUT Datatype: U16 Unit: - Def: 0
P-Group: TECH Active: first confirm QuickComm.: No Max: 13
Selects mode of timer 3. P2859, P2860, P2861 are the inputs of the timer, outputs are P2862, P2863.
Possible Settings:
0 ON delay (seconds)
1 OFF delay (seconds)
2 ON/OFF delay (seconds)
3 Pulse generator (seconds)
10 ON delay (minutes)
11 OFF delay (minutes)
12 ON/OFF delay (minutes)
13 Pulse generator (minutes)
Dependency:
P2802[2] is active level for the timer.
r2862 BO: Timer 3 Min: -
Datatype: U16 Unit: - Def: -
P-Group: TECH Max: -
Displays output of timer 3. P2859, P2860, P2861 are the inputs of the timer, outputs are P2862, P2863.
Dependency:
P2802[2] is active level for the timer.
r2863 BO: Nout timer 3 Min: -
Datatype: U16 Unit: - Def: -
P-Group: TECH Max: -
Displays Not-output of timer 3. P2859, P2860, P2861 are the inputs of the timer, outputs are P2862, P2863.
Dependency:
P2802[2] is active level for the timer.
P2864 BI: Timer 4 Min: 0:0
CStat: CUT Datatype: U32 Unit: - Def: 0:0
P-Group: TECH Active: first confirm QuickComm.: No Max: 4000:0
Define input signal of timer 4. P2864, P2865, P2866 are the inputs of the timer, outputs are P2867, P2868.
Dependency:
P2802[3] is active level for the timer.
P2865 Delay time of timer 4 Min: 0.0
CStat: CUT Datatype: Float Unit: - Def: 0.0
P-Group: TECH Active: first confirm QuickComm.: No Max: 9999.9
Defines delay time of timer 4. P2864, P2865, P2866 are the inputs of the timer, outputs are P2867, P2868.
Dependency:
P2802[3] is active level for the timer.
Level
3
Level
3
Level
3
Level
3
Level
3
Level
3
Level
3
Level
3