Issue 01/06 Parameter Description
MICROMASTER 440 Parameter List
6SE6400-5BB00-0BP0
31
r0031 CO: Act. filtered torque Min: -
Datatype: Float Unit: Nm Def: -
P-Group: CONTROL Max: -
Displays electrical torque.
iZ
L
L
2
3
m
sqrdp
R
m
M
â‹…
Ψ
â‹…â‹…â‹…=
:
m
M
:
L
m
:
L
R
:
rd
Ψ
:
Z
p
:
i
sq
:e
Motor torque
Pole pair number
Rotor flux
Rotor inductance
Magnetizing inductance
Torque-generating current
Motor counter EMF
Valid for V/f-caracteristic:
e
|
i
|
R
cos |
i
| u
i
s
s
2
s
sq
⋅−ϕ⋅⋅
≈
Output value will be zero at low speeds when the current injection is active (r1751.5 = 1).
Note:
The electrical torque is not the same as the mechanical torque, which can be measured on the shaft. Due to
windage and friction a part of the electrical torque is lost in the motor.
r0032 CO: Act. filtered power Min: -
Datatype: Float Unit: - Def: -
P-Group: CONTROL Max: -
Displays motor power (power output at the motor shaft).
Motor
ω, M
M f 2 M P
mech
⋅⋅π⋅=⋅ω=
⇒
[Nm] r0031 [1/min]
60
r0022
Ï€ 2
1000
1
[kW] r0032 â‹…â‹…â‹…â‹…=
[kW] r0032 0.75 [hp] r0032 â‹…=
Dependency:
Value is displayed in [kW] or [hp] depending on setting for P0100 (operation for Europe / North America).
r0035[3] CO: Act. motor temperature Min: -
Datatype: Float Unit: °C Def: -
P-Group: MOTOR Max: -
Displays measured motor temperature.