Parameter Description  Issue 01/06 
  MICROMASTER 440    Parameter List 
206  6SE6400-5BB00-0BP0 
r2090  BO: Control word 1 from CB Min: - 
  Datatype: U16 Unit: -  Def:  - 
P-Group:  COMM     Max:  - 
Displays control word 1 received from communication board (CB). 
Bitfields: 
Bit00   ON/OFF1                                    0  NO         1  YES 
Bit01   OFF2: Electrical stop                      0  YES        1  NO 
Bit02   OFF3: Fast stop                            0  YES        1  NO 
Bit03   Pulses enabled                             0  NO         1  YES 
 
Bit04   RFG enable                                 0  NO         1  YES 
Bit05   RFG start                                  0  NO         1  YES 
Bit06   Setpoint enable                            0  NO         1  YES 
Bit07   Fault acknowledge                          0  NO         1  YES 
 
Bit08   JOG right                                  0  NO         1  YES 
Bit09   JOG left                                   0  NO         1  YES 
Bit10   Control from PLC                           0  NO         1  YES 
Bit11   Reverse (setpoint inversion)               0  NO         1  YES 
 
Bit13   Motor potentiometer MOP up                 0  NO         1  YES 
Bit14   Motor potentiometer MOP down               0  NO         1  YES 
Bit15   CDS Bit 0 (Local/Remote)                   0  NO         1  YES 
Details: 
See relevant communication board manual for protocol definition and appropriate settings. 
r2091  BO: Control word 2 from CB Min: - 
  Datatype: U16 Unit: -  Def:  - 
P-Group:  COMM     Max:  - 
Displays control word 2 received from communication board (CB). 
Bitfields: 
Bit00   Fixed frequency Bit 0                      0  NO         1  YES 
Bit01   Fixed frequency Bit 1                      0  NO         1  YES 
Bit02   Fixed frequency Bit 2                      0  NO         1  YES 
Bit03   Fixed frequency Bit 3                      0  NO         1  YES 
 
Bit04   Drive data set (DDS) Bit 0                 0  NO         1  YES 
Bit05   Drive data set (DDS) Bit 1                 0  NO         1  YES 
Bit08   PID enabled                                0  NO         1  YES 
Bit09   DC brake enabled                           0  NO         1  YES 
 
Bit11   Droop enabled                              0  NO         1  YES 
Bit12   Torque control                             0  NO         1  YES 
Bit13   External fault 1                           0  YES        1  NO 
Bit15   Command data set (CDS) Bit 1               0  NO         1  YES 
Details: 
See relevant communication board manual for protocol definition and appropriate settings. 
 
Level 
3 
Level 
3