P1135[3]  OFF3 ramp-down time Min: 0.00 
CStat:  CUT  Datatype: Float Unit: s  Def:  5.00 
P-Group:  SETPOINT  Active: first confirm  QuickComm.: Yes  Max:  650.00 
Defines ramp-down time from maximum frequency to standstill for OFF3 command. 
f
f max
(P1082)
f
2
0
P1135
t
down,OFF3
 P1082 
f
 
 P1135 
t
 2
3OFF,down
â‹…=
OFF3
P2168
P2167
r0052 Bit02
Operation
Pulse
cancellation
t
t
t
P2168
f
act ,motor
f
act ,inverter
 
Index: 
P1135[0]  :  1st. Drive data set (DDS) 
P1135[1]  :  2nd. Drive data set (DDS) 
P1135[2]  :  3rd. Drive data set (DDS) 
Note: 
This time may be exceeded if the VDC_max. level is reached. 
P1140[3]  BI: RFG enable Min: 0:0 
CStat:  CT  Datatype: U32 Unit: -  Def:  1:0 
P-Group:  COMMANDS  Active: first confirm  QuickComm.: No  Max:  4000:0 
Defines command source of RFG enable command (RFG: ramp function generator). If binary input is equal 
to zero then the RFG output will be set immediately to 0. 
Index: 
P1140[0]  :  1st. Command data set (CDS) 
P1140[1]  :  2nd. Command data set (CDS) 
P1140[2]  :  3rd. Command data set (CDS) 
P1141[3]  BI: RFG start Min: 0:0 
CStat:  CT  Datatype: U32 Unit: -  Def:  1:0 
P-Group:  COMMANDS  Active: first confirm  QuickComm.: No  Max:  4000:0 
Defines command source of RFG start command (RFG: ramp function generator). If binary input is equal to 
zero then the RFG output is held at it present value. 
Index: 
P1141[0]  :  1st. Command data set (CDS) 
P1141[1]  :  2nd. Command data set (CDS) 
P1141[2]  :  3rd. Command data set (CDS) 
P1142[3]  BI: RFG enable setpoint Min: 0:0 
CStat:  CT  Datatype: U32 Unit: -  Def:  1:0 
P-Group:  COMMANDS  Active: first confirm  QuickComm.: No  Max:  4000:0 
Defines command source of RFG enable setpoint command (RFG: ramp function generator). If binary input 
is equal to zero then the RFG input will be set to zero and the RFG output will be ramp-down to zero. 
Index: 
P1142[0]  :  1st. Command data set (CDS) 
P1142[1]  :  2nd. Command data set (CDS) 
P1142[2]  :  3rd. Command data set (CDS) 
r1170  CO: Frequency setpoint after RFG Min: - 
  Datatype: Float Unit: Hz  Def:  - 
P-Group:  SETPOINT     Max:  - 
Displays overall frequency setpoint after ramp generator. 
 
Level 
2 
Level 
3 
Level 
3 
Level 
3 
Level 