Issue 01/06 Parameter Description
MICROMASTER 440 Parameter List
6SE6400-5BB00-0BP0
35
t
r0054
Bit00
ON/OFF1
ON
t
r0054
Bit11
Reverse
0 t
f
act
t
r0052
Bit02
Drive running
t
r0052
Bit14
Motor runs
right
left
not defined
last state is displayed
r0052 Bit14 "Motor runs right" ==> see below
Details:
The 7-segment display of the bit-parameters (binary parameters) is explained in the Introduction of the
Parameter List.
r0053 CO/BO: Act. status word 2 Min: -
Datatype: U16 Unit: - Def: -
P-Group: COMMANDS Max: -
Displays second status word of inverter (in bit format).
Bitfields:
Bit00 DC brake active 0 NO 1 YES
Bit01 f_act > P2167 (f_off) 0 NO 1 YES
Bit02 f_act <= P1080 (f_min) 0 NO 1 YES
Bit03 Act. current r0027 > P2170 0 NO 1 YES
Bit04 f_act > P2155 (f_1) 0 NO 1 YES
Bit05 f_act <= P2155 (f_1) 0 NO 1 YES
Bit06 f_act >= setpoint 0 NO 1 YES
Bit07 Act. Vdc r0026 < P2172 0 NO 1 YES
Bit08 Act. Vdc r0026 > P2172 0 NO 1 YES
Bit09 Ramping finished 0 NO 1 YES
Bit10 PID output r2294 == P2292 (PID_min) 0 NO 1 YES
Bit11 PID output r2294 == P2291 (PID_max) 0 NO 1 YES
Bit14 Download data set 0 from AOP 0 NO 1 YES
Bit15 Download data set 1 from AOP 0 NO 1 YES
Note:
- r0053 Bit00 ==> see parameter P1233
- r0053 Bit01 ==> see parameter P2167
- r0053 Bit02 ==> see parameter P1080
- r0053 Bit03 ==> see parameter P2170
- r0053 Bit04 ==> see parameter P2155
- r0053 Bit05 ==> see parameter P2155
- r0053 Bit06 ==> see parameter P2150
- r0053 Bit07 ==> see parameter P2172
- r0053 Bit08 ==> see parameter P2172