MICROMASTER 440 Parameter List
18 6SE6400-5BB00-0BP0
Drive Datasets (DDS)
ParNo Parameter text
P0005[3] Display selection
r0035[3] CO: Act. motor temperature
P0291[3] Inverter protection
P0300[3] Select motor type
P0304[3] Rated motor voltage
P0305[3] Rated motor current
P0307[3] Rated motor power
P0308[3] Rated motor cosPhi
P0309[3] Rated motor efficiency
P0310[3] Rated motor frequency
P0311[3] Rated motor speed
r0313[3] Motor pole pairs
P0314[3] Motor pole pair number
P0320[3] Motor magnetizing current
r0330[3] Rated motor slip
r0331[3] Rated magnetization current
r0332[3] Rated power factor
r0333[3] Rated motor torque
P0335[3] Motor cooling
P0340[3] Calculation of motor parameters
P0341[3] Motor inertia [kg*m^2]
P0342[3] Total/motor inertia ratio
P0344[3] Motor weight
r0345[3] Motor start-up time
P0346[3] Magnetization time
P0347[3] Demagnetization time
P0350[3] Stator resistance (line-to-line)
P0352[3] Cable resistance
P0354[3] Rotor resistance
P0356[3] Stator leakage inductance
P0358[3] Rotor leakage inductance
P0360[3] Main inductance
P0362[3] Magnetizing curve flux 1
P0363[3] Magnetizing curve flux 2
P0364[3] Magnetizing curve flux 3
P0365[3] Magnetizing curve flux 4
P0366[3] Magnetizing curve imag 1
P0367[3] Magnetizing curve imag 2
P0368[3] Magnetizing curve imag 3
P0369[3] Magnetizing curve imag 4
ParNo Parameter text
r0370[3] Stator resistance [%]
r0372[3] Cable resistance [%]
r0373[3] Rated stator resistance [%]
r0374[3] Rotor resistance [%]
r0376[3] Rated rotor resistance [%]
r0377[3] Total leakage reactance [%]
r0382[3] Main reactance [%]
r0384[3] Rotor time constant
r0386[3] Total leakage time constant
P0400[3] Select encoder type
P0408[3] Encoder pulses per revolution
P0491[3] Reaction on freq. signal loss
P0492[3] Allowed frequency difference
P0494[3] Delay frequency loss reaction
P0500[3] Technological application
P0530[3] Unit for positioning signal
P0531[3] Unit conversion
P0601[3] Motor temperature sensor
P0604[3] Threshold motor temperature
P0625[3] Ambient motor temperature
P0626[3] Overtemperature stator iron
P0627[3] Overtemperature stator winding
P0628[3] Overtemperature rotor winding
r0630[3] CO: Ambient temperature
r0631[3] CO: Stator iron temperature
r0632[3] CO: Stator winding temperature
r0633[3] CO: Rotor winding temperature
P0640[3] Motor overload factor [%]
P1001[3] Fixed frequency 1
P1002[3] Fixed frequency 2
P1003[3] Fixed frequency 3
P1004[3] Fixed frequency 4
P1005[3] Fixed frequency 5
P1006[3] Fixed frequency 6
P1007[3] Fixed frequency 7
P1008[3] Fixed frequency 8
P1009[3] Fixed frequency 9
P1010[3] Fixed frequency 10
P1011[3] Fixed frequency 11
P1012[3] Fixed frequency 12