Parameter Description  Issue 01/06 
  MICROMASTER 440    Parameter List 
60  6SE6400-5BB00-0BP0 
P0352[3] Cable resistance Min: 0.0 
CStat:  CUT  Datatype: Float Unit: Ohm  Def:  0.0 
P-Group:  MOTOR  Active: Immediately  QuickComm.: No  Max:  120.0 
Describes cable resistance between inverter and motor for one phase. 
 
d
M
l
l :  Cable length d :  Cable diameter
A :  Cable cross-section
    :  Specific resistanceρ
A
l
    R ⋅ρ=
2
2
d
    A
⋅π=
m
 mm   
 0,0178  
2
Cu
⋅Ω
=
ρ
Inverter
 
Index: 
P0352[0]  :  1st. Drive data set (DDS) 
P0352[1]  :  2nd. Drive data set (DDS) 
P0352[2]  :  3rd. Drive data set (DDS) 
P0354[3] Rotor resistance Min: 0.0 
CStat:  CUT  Datatype: Float Unit: Ohm  Def:  10.0 
P-Group:  MOTOR  Active: Immediately  QuickComm.: No  Max:  300.0 
Sets rotor resistance of motor equivalent circuit (phase value). 
Index: 
P0354[0]  :  1st. Drive data set (DDS) 
P0354[1]  :  2nd. Drive data set (DDS) 
P0354[2]  :  3rd. Drive data set (DDS) 
Dependency: 
Calculated automatically using the motor model or determined using P1910 (motor identification). 
P0356[3]  Stator leakage inductance Min: 0.00001 
CStat:  CUT  Datatype: Float Unit: -  Def:  10.00000 
P-Group:  MOTOR  Active: Immediately  QuickComm.: No  Max:  1000.00000 
Sets stator leakage inductance [mH] of motor equivalent circuit (phase value). 
 
1000
0356P
0310P2
L
f2
LX
SSS
⋅⋅π⋅=⋅⋅π⋅=⋅ω=
σσσ
Stator leakage reactance:
 
Index: 
P0356[0]  :  1st. Drive data set (DDS) 
P0356[1]  :  2nd. Drive data set (DDS) 
P0356[2]  :  3rd. Drive data set (DDS) 
Dependency: 
Calculated automatically using the motor model or determined using P1910 (motor identification). 
P0358[3]  Rotor leakage inductance Min: 0.0 
CStat:  CUT  Datatype: Float Unit: -  Def:  10.0 
P-Group:  MOTOR  Active: Immediately  QuickComm.: No  Max:  1000.0 
Sets rotor leakage inductance [mH] of motor equivalent circuit (phase value). 
 
1000
0358P
0310P2
L
f2
LX
RRR
⋅⋅π⋅=⋅⋅π⋅=⋅ω=
σσσ
Rotor leakage reactance:
 
Index: 
P0358[0]  :  1st. Drive data set (DDS) 
P0358[1]  :  2nd. Drive data set (DDS) 
P0358[2]  :  3rd. Drive data set (DDS) 
Dependency: 
Calculated automatically using the motor model or determined using P1910 (motor identification). 
Level 
3 
Level 
4 
Level 
4 
Level 
4