Function Diagrams Issue 01/06
MICROMASTER 440 Parameter List
278 6SE6400-5BB00-0BP0
- 3400 -
Function diagram
87654321
3400_PIDMOP.vsd
Internal Setpoint Source
MICROMASTER 440
16.01.2006 V2.1
PID Motor Potentiometer (PID-MOP)
(19:13)
BI: PID-MOP (UP)
P2235.C
(19:14)
BI: PID-MOP (DWN)
P2236.C
0 1
1 0
1 1
0 0
-1
Max. frequency
0.00 ... 650.00 [Hz]
P1082.D (50.00)
PID-MOP
RFG
PID-MOP output start value
control
Setp. of PID-MOP
-200.00 ... 200.00 [%]
P2240.D (10.00)
PID-MOP setp. mem.
0 ... 1
P2231.D (0)
Inh. neg. PID-MOP
0 ... 1
P2232 (1)
0
1
r2250
CO: MOP outp. setp
100 %
%
Rated frequency
12.00 ... 650.00 [Hz]
P0310.D (50.00)