Issue 01/06 Parameter Description
MICROMASTER 440 Parameter List
6SE6400-5BB00-0BP0
257
3.40 Inverter parameters
P3900 End of quick commissioning Min: 0
CStat: C Datatype: U16 Unit: - Def: 0
P-Group: QUICK Active: first confirm QuickComm.: Yes Max: 3
Performs calculations necessary for optimized motor operation.
After completion of calculation, P3900 and P0010 (parameter groups for commissioning) are automatically
reset to their original value 0.
Possible Settings:
0 No quick commissioning
1 Start quick commissioning with factory reset
2 Start quick commissioning
3 Start quick commissioning only for motor data
Dependency:
Changeable only when P0010 = 1 (quick commissioning)
Note:
P3900 = 1 :
When setting 1 is selected, only the parameter settings carried out via the commissioning menu "Quick
commissioning", are retained; all other parameter changes, including the I/O settings, are lost. Motor
calculations are also performed.
P3900 = 2 :
When setting 2 is selected, only those parameters, which depend on the parameters in the commissioning
menu "Quick commissioning" (P0010 = 1) are calculated. The I/O settings are also reset to default and the
motor calculations performed.
P3900 = 3 :
When setting 3 is selected, only the motor and controller calculations are performed. Exiting quick
commissioning with this setting saves time (for example, if only motor rating plate data have been changed).
Calculates a variety of motor parameters, overwriting previous values (see parameter P0340, setting P0340
= 1).
P3950 Access of hidden parameters Min: 0
CStat: CUT Datatype: U16 Unit: - Def: 0
P-Group: ALWAYS Active: first confirm QuickComm.: No Max: 255
Accesses special parameters for development (expert only) and factory functionality (calibration parameter).
r3954[13] CM version and GUI ID Min: -
Datatype: U16 Unit: - Def: -
P-Group: - Max: -
Used to classify firmware (only for SIEMENS internal purposes).
Index:
r3954[0] : CM version (major release)
r3954[1] : CM version (minor release)
r3954[2] : CM version (baselevel or patch)
r3954[3] : GUI ID
r3954[4] : GUI ID
r3954[5] : GUI ID
r3954[6] : GUI ID
r3954[7] : GUI ID
r3954[8] : GUI ID
r3954[9] : GUI ID
r3954[10] : GUI ID
r3954[11] : GUI ID major release
r3954[12] : GUI ID minor release
Level
1
Level
4
Level
4