Issue 01/06 Parameter Description
MICROMASTER 440 Parameter List
6SE6400-5BB00-0BP0
63
P0364[3] Magnetizing curve flux 3 Min: 0.0
CStat: CUT Datatype: Float Unit: % Def: 115.0
P-Group: MOTOR Active: Immediately QuickComm.: No Max: 300.0
Specifies third flux value of saturation characteristic in [%] relative to rated motor voltage (P0304).
Index:
P0364[0] : 1st. Drive data set (DDS)
P0364[1] : 2nd. Drive data set (DDS)
P0364[2] : 3rd. Drive data set (DDS)
Details:
See P0362 (magnetizing curve flux 1).
P0365[3] Magnetizing curve flux 4 Min: 0.0
CStat: CUT Datatype: Float Unit: % Def: 125.0
P-Group: MOTOR Active: Immediately QuickComm.: No Max: 300.0
Specifies fourth flux value of saturation characteristic in [%] relative to rated motor voltage (P0304).
Index:
P0365[0] : 1st. Drive data set (DDS)
P0365[1] : 2nd. Drive data set (DDS)
P0365[2] : 3rd. Drive data set (DDS)
Details:
See P0362 (magnetizing curve flux 1).
P0366[3] Magnetizing curve imag 1 Min: 0.0
CStat: CUT Datatype: Float Unit: % Def: 50.0
P-Group: MOTOR Active: Immediately QuickComm.: No Max: 500.0
Specifies first magnetizing current value of the saturation characteristic in [%] relative to the rated
magnetizing current (P0331).
Index:
P0366[0] : 1st. Drive data set (DDS)
P0366[1] : 2nd. Drive data set (DDS)
P0366[2] : 3rd. Drive data set (DDS)
Dependency:
Affects P0320 (motor magnetizing current).
Details:
See P0362 (magnetizing curve flux 1).
P0367[3] Magnetizing curve imag 2 Min: 0.0
CStat: CUT Datatype: Float Unit: % Def: 75.0
P-Group: MOTOR Active: Immediately QuickComm.: No Max: 500.0
Specifies second magnetizing current value of saturation characteristic in [%] relative to rated magnetizing
current (P0331).
Index:
P0367[0] : 1st. Drive data set (DDS)
P0367[1] : 2nd. Drive data set (DDS)
P0367[2] : 3rd. Drive data set (DDS)
Dependency:
Affects P0320 (motor magnetizing current).
Details:
See P0362 (magnetizing curve flux 1).
P0368[3] Magnetizing curve imag 3 Min: 0.0
CStat: CUT Datatype: Float Unit: % Def: 135.0
P-Group: MOTOR Active: Immediately QuickComm.: No Max: 500.0
Specifies third magnetizing current value of saturation characteristic in [%] relative to rated magnetizing
current (P0331).
Index:
P0368[0] : 1st. Drive data set (DDS)
P0368[1] : 2nd. Drive data set (DDS)
P0368[2] : 3rd. Drive data set (DDS)
Dependency:
Affects P0320 (motor magnetizing current).
Details:
See P0362 (magnetizing curve flux 1).
Level
4
Level
4
Level
4
Level
4
Level
4
www . ElectricalPartManuals . com