EasyManua.ls Logo

Siemens MICROMASTER 440 - Table 5-2 Dimensions, required cooling air flow and tightening torques for power terminals

Siemens MICROMASTER 440
328 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function Diagrams Issue 01/06
MICROMASTER 440 Parameter List
264 6SE6400-5BB00-0BP0
- 2200 -
Function diagram
87654321
2200_ADC.vsd
External Interfaces
MICROMASTER 440
16.01.2006 V2.1
Analog Input (ADC)
D
A
Switching
bipolar
unipolar
Digit
Warning, signal lost
(F0080)
ADC after scal.[%] [%]
r0754 [2]
r0755 [2]
CO:ADC scal[4000h]
Act.ADC inp.[V/mA]
r0752 [2]
Type of ADC
0 ... 4
P0756 [2] (0)
Smooth time ADC
0 ... 10000 [ms]
P0753 [2] (3)
Value x1:ADC scal.
-20 ... 20
P0757 [2] (0)
Value y1:ADC scal.
-99999.9 ... 99999.9 [%]
P0758 [2] (0.0)
Value y2:ADC scal.
-99999.9 ... 99999.9 [%]
P0760 [2] (100.0)
Type of ADC
0 ... 4
P0756 [2] (0)
ADC deadband width
0 ... 20
P0761 [2] (0)
Delay on sig. loss
0 ... 10000 [ms]
P0762 [2] (10)
50 % of P0761
Volts or
mA
CO/BO: Bin.inp.val
r0722
r0722
Value x2:ADC scal.
-20 ... 20
P0759 [2] (10)
T
1
0
V3.91.7
1,3
Type of ADC
0 ... 4
P0756 [2] (0)
x
2
x
1
y
2
y
1
10 V or 20 mA
ASP
max
100 %
10 V
20 mA
V
mA
x
100%
%
x
d
ASP
min
4000 h
r0722
.6
.7
BO: ADC status Wd
r0751
Analog input
www . ElectricalPartManuals . com

Table of Contents