Table 9- 112 Condition codes
RET_VAL (W#16#....)
Description
0000
No error
8090 Invalid OB_NR parameter
80A0
No start date / time set for that interrupt OB
9.5.3.3
ACT_TINT (Activate time of day interrupt)
Table 9- 113 ACT_TINT (Activate date and time of day interrupt)
LAD / FBD
SCL
Description
ret_val:=ACT_TINT(_int_in_);
Activates the start date and
time of day interrupt event for
the specified interrupt OB.
Table 9- 114 Data types for the parameters
Parameter and type
Data type
Description
OB_NR
IN
OB_TOD (INT)
OB number (accepts symbolic name)
RET_VAL
OUT
Int
Execution condition code
Table 9- 115 Condition codes
RET_VAL (W#16#....)
Description
0000
No error
8090
Invalid OB_NR parameter
80A0 Start date and time-of day not set, for the relevant time-of-day
interrupt OB