EasyManua.ls Logo

Spectra T50e - Initiate Media Discovery Manually

Default Icon
539 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 8—Configuring and Using Media Lifecycle Management Using Media Lifecycle Management
August 2017 User GuideSpectra T50e Library
241
3. ClickSave.
4. TheblackoutperiodsyousettakeeffectwhenyouenablePostScanfor
individualpartitionsbyconfiguringoneormorePostScantriggers(see
EnableandConfigureMLMPreScanandPostScanonpage177).
USING MEDIA LIFECYCLE MANAGEMENT
Overview AfteryouenableMLMandconfiguretheglobalsettings(see
EnablingMLMandConfiguringGlobalSettingsonpage235),youare
readytobe gin usingMLMtotrackandmonitortheLTOcartridgesinthe
library.
Note: IfyouwanttousethePreScanandPostScanoptions,youmust
enableandconfiguretheseoptionsforeachpartition(seeEnable
andConfigureMLMPreScanandPostScanonpage177).
User Privilege Requirements SeeSpecifythePartitionUsersonpage181
forinformationaboutassigninguserstoapartition.
Onlyauserwithsuperuseroradministratorprivilegescanmanually
startandstopmediadiscovery(usingeitherMediaAutoDiscoveryor
PreScan),manuallystartandpausePostScanoperations,andmanage
theMLMandDLMdatabases.
Anyuserwithoperatorprivilegeswhoisassignedtothepartitionand
alluserswithsuperuseroradministratorprivilegescangenerateand
saveMLMreports.
Add Cartridges to the MLM Database
ThecartridgesusedinthelibraryarenotaddedtotheMLMdatabaseuntil
theyarediscovered.Theprocessyouusetodiscovercartridgesandadd
themtotheMLMdatabasedependsonwhenyouloadedthecartridges
intothelibrary.
Note: IfyouimportcartridgesintothelibrarywithMLMdisabled,
thosecartridgesarenotautomaticallydiscoveredandaddedto
theMLMdatabase.AfteryouenableMLM,youmustusethe
manualdiscoveryprocesstoaddthecartridgestotheMLM
database(see
InitiateMediaDiscoveryManuallyonpage243.
Important
If a cartridge is write-protected when it is inserted into a drive, the library cannot
update the MLM information on the cartridges MAM.
Important
The discovery process cannot begin while the library is actively loading cartridges
into drives. If you import cartridges during this time, the library posts a failure
message stating that no drives are available. Either wait until the library is idle
before importing cartridges or start the discovery process for the imported
cartridges manually when the library is idle.

Table of Contents

Other manuals for Spectra T50e

Related product manuals