Chapter 14—Maintaining the Library Updating the BlueScale Software and Library Firmware
August 2017 User Guide—Spectra T50e Library
421
NotallUSBdevicesarecompatiblewiththelibrary.Ifyou
areunabletoaccessaUSBdevicefromthelibrary,removeit
anduseadifferentone.
—OR—
Apreviouslyconfiguredpackageserver.
Prepare for the BlueScale Package Update
UsethefollowingsectionstopreparetoupdatetheBlueScalesoftware and
librarycomponentfirmware.
Make Sure Your BlueScale Software Support Key Is
Current
UpdatingtheBlueScalesoftwareandthefirmwareforthelibrary
componentsrequiresacurrentservicecontractwithSpectraLogic
TechnicalSupport.Ifyourservicecontractexpires,renewitasdescribedin
RenewingtheBlueScaleSoftwareSupportKeyonpage412.
Prepare the Library
Stopalllibrary‐andhost‐basedoperations.
BackupyourMLMdatabase(seeBackUptheMLMandDLM
Databasesonpage263).
Note: BackinguptheMLMdatabasealsobacksuptheDLMdatabase.
BackupallofyourBlueScaleencryptionkeys(seeExportingand
ProtectingEncryptionKeysonpage307).
DownloadandreadtheSpectraT50eLibraryReleaseNotesand
DocumentationUpdatesforthemostcurrentinformationaboutupdated
BlueScalepackages.
Confirm that all of the following conditions are met before beginning the update
process:
All backup processes are complete
All storage management software daemons are stopped
All drives are empty
To ensure that no commands are sent to the controllers, Spectra Logic suggests
disconnecting fibre cables to any tape drives used as a robotic exporter.
If the release notes provide special requirements or procedures for updating the
library, make sure that you follow them.