Chapter 12—Library TroubleshootingEmergency Magazine Removal
August 2017 User Guide—Spectra T50e Library
380
12. ClickRun.
Afterabriefdelay,theResultsscreendisplays,showingthatthe
databasewasrestored.
Note: AfteranMLMdatabaserestore,theDiscover Mediabuttononthe
MediaLifecycleManagementToolsscreen(Maintenance >
MLM)maybeactiveevenifallcartridgeshavebeendiscovered.
EMERGENCY MAGAZINE REMOVAL
Ifyouneedtoremovethemagazinesinanemergencyinstance(for
example,ifyoucannotusethefrontpaneltoinstructthelibrarytounlock
themagazines)followthestepsinthissection.
1. Discontinueoperationsrunningonthelibrary.
a. Useyourstoragemanagementsoftwaretostopanybackupor
restoreoperationsrunningtothelibrary.
b. Useyourstoragemanagementsoftwaretomoveanycartridgesthat
arecurrentlyindrivesbacktotheirstoragelocations.
Ifyoucannotuseyourstoragemanagementsoftware,movethe
cartridgesasdescribedin
MoveCartridgesWithinaPartitionon
page219.
c. PausePostScanifitisrunning(seePausethePostScanProcesson
page254).Anytapescurrentlybeingscannedarereturnedtotheir
storagelocations.
2. Pressthefrontpanelpowerbuttonuntilthebutton’sLEDstartstoflash.
Waitforthepower‐offsequencetocomplete,whichallowsthe
applicationstoshutdowngracefully.
Do not perform this procedure if the library is powered on; if the library is powered
on, the robotics could attempt to load or unload a cartridge from a slot in the
magazine that is unlocked using the emergency magazine removal procedure. You
risk damaging the robotics, the magazines, or the library.
Do not use this magazine removal procedure unless specifically instructed to do so
by Spectra Logic Technical Support.