Chapter 8—Configuring and Using Media Lifecycle Management Using PostScan
August 2017 User Guide—Spectra T50e Library
252
Enable PostScan
PostScanisenabledbyselectingoneofthePostScanoptionsandoneor
morescantriggerswhenyouconfigureapartition(seeEnableand
ConfigureMLMPreScanandPostScanonpage177).Theavailable
PostScanoptionsdependonwhichgenerationofdrivesareinthepartition
andwhetherornotaGlobalSparedriveisassignedtothepartition.
Schedule a Manual PostScan
TheautomaticPostScantriggersonlyaddMLM‐enabledLTOdata
cartridgestothePostScanqueue.However,cartridgescanalsobeaddedto
thePostScanqueuemanually.Thisisespeciallyusefulifyourlibrary
containsLTOcartridgesthatarenotMLM‐enabled.Youcanalsousethe
manualPostScanprocesstoverifyasuspectMLM‐enabledcartridgeeven
ifitwaspreviouslyscanned.
CartridgesthataremanuallyaddedtothePostScanqueueareprocessed
beforecartridgesthatwereaddedasaresultofthetriggercriteriaforthe
partition.TheyareprocessedusingthePostScanoptionthatwasspecified
forthepartition.
Global Spare Drives BothFullScanandQuickScanusing GlobalSparerequireaGlobalSparedrive.
AlthoughaGlobalSparedrivecanbesharedbymultiplepartition s,assigninga
separateGlobalSparedrivetoeachpartitionisrecommended.Eachpartition
canthe nperformPostScanwhenevertheprerequisitesaremet,withoutwaiting
forPostScaninanother
partitiontocomplete.
Blackout Periods Becausethestoragemanagementsoftwarecanpotentiallyrequestatapethatis
currentlyundergoingverification,youcanconfigureblackoutperiodsduring
whichthePostScanoperationissuspended.Configuringblackoutperiods
ensuresthatPostScandoesnotoperateduringyournormalbackupwindow.
Theblackoutperiodsapplytoallofthestoragepartitions
inthelibrary.See
ConfigurePostScanBlackoutPeriodsonpage239forinstructions.
Cleaning Partitions ThePostScanfeaturecannotbeenabledforacleaningpartitionanddoesnot
affectcleaningtapes.
Consideration Description
PostScan is enabled and configured for each individual partition. PostScan does not
operate until the PostScan option is selected and one or more triggers are specified
for the partition are reached
.