Chapter 13—Drive Troubleshooting Retrieving a Drive Trace or Drive Dump File
August 2017 User Guide—Spectra T50e Library
394
RETRIEVING A DRIVE TRACE OR DRIVE DUMP FILE
SpectraLogicusesdrivetracesanddrivedumpstohelpdiagnose
problemswithadrive.Adrivetraceisasetoflogscollectedbythelibrary
tohelpdiagnosedriveerrors.Adrivedumpisafilegeneratedbythedrive
whenitencountersanerrorstate.Youonlyneedtoretrieveadrivetraceor
drivedumpwheninstructedtodosobySpectraLogicTechnicalSupport.
F DriveFibreChannelerror.
TheFibreChanneldrivedoesnotdetectlightorarelateddiagnosticfailedto
detectlightthroughthefiberopticconnectiontothedrive.
Verifythefibercablesandconnectionsbetweenthedriveandthehostarethe
correcttypeandareworkingproperly.Verifyallequipmentanddevicesare
poweredON.
Verifytheconfigurationsettingsforthedrivearesetcorrectlyandare
compatiblewiththetopologyofthenetwork.
VerifythatthehostFibreChanneladapterandportareworkingproperlyand
arecompatiblewiththetopologyofthenetwork.
VerifythattheFibreChannelswitchportsareworkingproperlyandare
compatiblewiththetopologyofthenetwork.
VerifythatthefibercableisconnectedtoPortA(0)ofthedrive.
VerifythatPortA(0)ontheFibreChanneldriveisworkingproperlybyusing
ITDTtorunthe“FunctionCode6:RunHostInterfaceWrapTest.”
J IncompatibleMedia.
Thedrivedeterminedthatincompatiblemediawasloadedintothedrive.
P Thecartridgeinthedriveiswrite‐protected.Thestoragemanagementsoftware
cannotwritedatatoawrite‐protectedcartridge.Thelibrarycannotupdatethe
cartridgeMAMwhenthecartridgeiswrite‐protected.
u Firmwareupdateisinprogress.
b, c, H, h,
n, o
N/A Reservedornotactivelyinuse,ornoerrorormessageassigned.
TheremaybeaproblemwiththeSCD.Resetthedriveanddeterminewhether
allsegmentsontheSCDarelit.
Iftheyarealllit,confirmthatthedriveisusingthecurrentfirmwareversion
(see
UpdatingDriveFirmwareonpage443)andupdatethefirmwareif
necessary.
Iftheproblempersists,contactSpectraLogicTechnicalSupport(see
ContactingSpectraLogiconpage7).
… N/A Themessagedisplayhaslostcommunicationwiththedrive.Thismessage
appearsonLine2ofthemes sagedisplay.Thethreedotsmayoccasionally
displayduringnormalprocessing.
Code
DLM
Health
Icon
Cause and Solution