Chapter 8—Configuring and Using Media Lifecycle Management Using MLM Reporting
August 2017 User GuideSpectra T50e Library
263
Override a Poor Cartridge Health Report
Undercertaincircumstancesyoumayneedtooverridethehealthofan
MLMenabledcartridgethatisreportedaspoor(aredhealthiconappears
nexttothecartridgebarcode).Whenthecartridgehealthispoor,agreen
arrowbuttonappears,thatcanbeusedtooverridethereportedhealth.
Duringtheoverrideprocess,thelibraryprogressivelyeliminatesany
recentharderrorsfromthetapehealthcalculation.Ifthehealthisstillred,
allharderrorsareeliminatedfromthetapehealthcalculation.Thelibrary
continuestousethisadjustedtapehealthuntilthecartridgehealthreturns
toeitherGoodorAverageaspartofnormalhealthmonitoring.
Usethefollowingstepstoresetthehealthofasinglecartridge.
1. DisplaytheMLMReportsscreenasdescribedinGenerateMLM
Reportsonpage255.
2. Locatethebarcodeofthecartridgeforwhichyouneedtoresetthe
health(seeStep7onpage259).
3. Clickthegreenarrowbuttonforthecartridge.Thelibraryadjusts
parametersusedtocalculatethetapehealthuntilthereportedhealthis
Average.
4. Attempttoresolvetheissuesthatwerecausingthemediahealthtobe
reportedaspoor.
Important
Do not reset the cartridge health unless you believe that the reported poor health
is due to drive problems and not the cartridge or you are specifically directed to do
so by Spectra Logic Technical Support.
Figure 164 Select the green override button to reset the reported
health for an MLM-enabled LTO cartridge.
Override MLM
health