Chapter 12—Library Troubleshooting Troubleshooting MLM Issues
August 2017 User GuideSpectra T50e Library
353
TROUBLESHOOTING MLM ISSUES
Thissectionprovidesinformationaboutpotentialissuesthatyoumay
experiencewhileusingMLM.
Issue Cause Resolution
An asterisk (*)
appears next to the
barcode on the
MLM Details screen
or an MLM report.
Thecartridgewasexportedfromthelibrary. Ifyoudonotintendto
reimportthecartridge,you
candeleteitfromtheMLM
database(see
DeleteMLM
RecordsFromtheDatabaseon
page268).
An “x” appears next
to a barcode in the
Inventory screen.
Thecleaningcartridgeisexpired. Exporttheexpiredcartridge
orexchangeitforanewone
(see
ExportingorExchanging
Cartridgesonpage207).
The library does not
proactively discover
new cartridges
when they are
imported.
Thediscoveryprocess(MediaAutoDiscovery
orPreScan)cannotbeginwhilethehostsare
activelyloadingcartridgesintoorunloading
cartridgesfromthedrives.Ifyouimport
cartridgesduringthistime,thelibrarypostsa
failuremessagestatingthatnodrivesare
availabletoperformthediscoveryprocess.
Eitherwaituntilthelibraryis
idlebeforebeginningan
importoperationormanually
startthediscoveryprocessfor
importedcartridgeswhenthe
libraryisidle.See
Initiate
MediaDiscoveryManuallyon
page243forinstructions.
The media health
reported by MLM
for LTO-4 media
changed after it was
loaded into an
LTO-5 or LTO-6
drive.
ThealgorithmusedtodetermineMLMmedia
healthinLTO5andlatergenerationdrives
differsfromthealgorithmusedforLTO4
drives.ForBlueScalesoftwareversionsearlier
thanBlueScale12.0.7,whenLTO4mediais
usedinbothLTO4andLTO5orLTO6
drives,themediahealth
reportedbyMLMis
inconsistentbetweenthetwodrive
generations.
BeginningwithBlueScale12.0.7,afteran
LTO4cartridgeisloadedintoanLTO5or
latergenerationdrive,thelibraryadjuststhe
algorithmusedtocalculatethemediahealth
scorewheneverthecartridgeissubsequently
loadedintoanLTO4drive.Thisadjustment
ensuresthatthereportedmediahealthis
consistent,regardlessofwhethertheLTO
4
cartridgeisusedinanLTO4oranLTO5or
latergenerationdrive.
Asabestpracticeforyour
LTO4media,SpectraLogic
recommendsthatyou
configureLTO4andLTO5or
latergenerationdrivesin
separatepartitionsandthat
youdonotroutinelyshare
LTO4mediabetweenLTO4
andLTO5orlatergeneration
drives.