377
9. ClickNext.IfyouarerestoringfromaUSBdeviceconnectedtothe
LCM,usetheSelect a restore stampdropdownlisttoselectthebackup
fileyouwanttouse.Thebackupfilesarenamed<date-time>cfg.zip,
where<date-time>isthetimestampforwhenthefilewascreated.
10. ClickRun.
Afterabriefdelay,theResultsscreendisplaysshowingthatthe
configurationwasrestored.Thelibrarythenperformsapowercycle
reset.
11. Oncethelibrarybeginsitspoweronsequence,removetheUSBdevice
ifnecessary.
12. Ifyouimportedcartridgesintoapartitionafteryougeneratedthe
backupconfigurationfile,seeRestoreOtherConfigurationChangeson
page371.
13. Ifnecessary,restoretheMLMandDLMdatabasesasdescribedin
RestoretheMLMandDLMDatabasesonpage377.
Restore the MLM and DLM Databases
UsethefollowingstepstorestoretheMLMdatabasefromapreviously
savedbackupthatwascreatedusingtheSaveMLMDatabaseutility(see
BackUptheMLMandDLMDatabasesonpage263).
Notes: RestoringtheMLMdatabasealsorestorestheDLMdatabase.
YoucanalsorestoretheMLMandDLMdatabasesusingan
AutoConfigurationSavebackupfile(see
RestoreFroman
AutoConfigurationSaveFileonpage368).
1. Useyourstoragemanagementsoftwaretostopallbackuporrestore
operationsonthelibrary.
Important
Before the library is restored using a saved configuration file on the USB device, the
current configuration is saved to the USB device with a time stamp indicating when
the file was created. The library is then restored using the selected auto saved
configuration.
The USB device now contains one additional configuration file.
Important
If you do not remove the USB device, the library power-on sequence fails.
If the library fails to boot, power off the library as described in Power Off the Library
on page 136. Once the library is powered off, remove the USB device and power on
the library as described in Power On the Library on page 135.
Caution
The Restore MLM Database from USB utility overwrites the existing MLM and DLM
databases with the versions previously saved on the USB device.
Important
Restoring the MLM and DLM databases requires the library to be idle.