Chapter 13—Drive Troubleshooting Troubleshooting Drives
August 2017 User Guide—Spectra T50e Library
385
4. Ifyouexperienceproblemsaccessingthedrivesinthelibraryfromthe
storagemanagementsoftwareonthehost,checkthefollowing:
Check... To...
Interface
connections
Makesurethattheconnectionstothedrivesaresecure.SeeTroubleshooting
LibraryHardwareIssuesonpage347driveinterfaceissues.
Important: After you power on the library and the Fibre Channel arbitrated
loop or fabric completes its initialization, avoid disconnecting the Fibre
Channel drives from the network. If you need to disconnect a drive from the
network, use the utility provided with your switch or hub to bypass the
affected ports before breaking the connection. The bypass sets the port to a
non-participating state on the network. After you reconnect the drive to the
library, use the utility to return the port to a participating state.
Software
installation
Makesurethatyourhostapplicationisinstalledandconfiguredcorrectly(refer
toyoursoftwaredocumentation).Payspecialattentiontostepsthatdescribe
howtoconfigurethesoftwareforusewiththedrive(s).
Driveaddressing Makesurethatthedriveaddressconfiguredinthehostapplicationisthesame
oneyouspecifiedwhenyouconfiguredthepartitioncontainingthedrive(see
CreatingaStoragePartitiononpage169).
Hostandsoftware
documentation
Determinewhetheradevicedriverisrequired.Someoperatingenvironments
requireyoutoinstalldevicedriversbeforetheapplicationsoftwarecan
correctlycommunicatewiththedrives.Whenyouupdatethedrivefirmware,
youmayalsoneedtoupdatethedevicedriverforthedrive.See
Updating
DriveDeviceDriversonpage455forinstructions.