EasyManua.ls Logo

Spectra T50e - Using DLM to Test an LTO Drive

Default Icon
539 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 13—Drive Troubleshooting Using a Global Spare Drive
August 2017 User GuideSpectra T50e Library
404
4. ClickMENU > Configuration > PartitionstodisplaythePartitions
screen.
5. ClickGlobal Spareforthepartitionthatcontainsthefaileddriveto
displaytheGlobalSpareUsagescreen.
Note: TheGlobalSparebuttonisnotpresentifadriveisnot
configuredasaGlobalSpareforthepartition(seeAssigna
GlobalSpareDriveonpage174).
6. ClickUse Sparenexttothedriveforwhichyouwanttosubstitutethe
GlobalSparedrive.Waitforthelibrarytocompletethesparing
operation.
Notes: Whenyouselectthedrivetoreplace,theBlueScalesoftware
disablestheselecteddriveandconfiguresanavailableGlobal
SparedrivetoreportthesameWWNandserialnumberas
thedriveitisreplacing. Thefaileddrivecanthenberemoved
andreplacedthenexttimeyouarephysicallyatthelibrary.
IfyouhavemorethanoneavailableGlobalSparedriv e,the
libraryautomaticallyselectsadriveinnoparticularorder.
Figure 273 Click Global Spare to begin the process of
replacing a partition drive with a Global Spare drive.
Figure 274 Click Use Spare for the drive you want to replace.