General-purpose timers (TIM2/TIM3/TIM4/TIM5) RM0440
1320/2126 RM0440 Rev 4
Bits 6:4 OC1M[2:0]: Output compare 1 mode
These bits define the behavior of the output reference signal tim_oc1ref from which tim_oc1
is derived. tim_oc1ref is active high whereas tim_oc1 active level depends on CC1P bit.
0000: Frozen - The comparison between the output compare register TIMx_CCR1 and the
counter TIMx_CNT has no effect on the outputs.(this mode is used to generate a
timing base).
0001: Set channel 1 to active level on match. tim_oc1ref signal is forced high when the
counter TIMx_CNT matches the capture/compare register 1 (TIMx_CCR1).
0010: Set channel 1 to inactive level on match. tim_oc1ref signal is forced low when the
counter TIMx_CNT matches the capture/compare register 1 (TIMx_CCR1).
0011: Toggle - tim_oc1ref toggles when TIMx_CNT=TIMx_CCR1.
0100: Force inactive level - tim_oc1ref is forced low.
0101: Force active level - tim_oc1ref is forced high.
0110: PWM mode 1 - In upcounting, channel 1 is active as long as TIMx_CNT<TIMx_CCR1
else inactive. In downcounting, channel 1 is inactive (tim_oc1ref=0) as long as
TIMx_CNT>TIMx_CCR1 else active (tim_oc1ref=1).
0111: PWM mode 2 - In upcounting, channel 1 is inactive as long as
TIMx_CNT<TIMx_CCR1 else active. In downcounting, channel 1 is active as long as
TIMx_CNT>TIMx_CCR1 else inactive.
1000: Retriggerable OPM mode 1 - In up-counting mode, the channel is active until a trigger
event is detected (on tim_trgi signal). Then, a comparison is performed as in PWM
mode 1 and the channels becomes inactive again at the next update. In down-
counting mode, the channel is inactive until a trigger event is detected (on tim_trgi
signal). Then, a comparison is performed as in PWM mode 1 and the channels
becomes inactive again at the next update.
1001: Retriggerable OPM mode 2 - In up-counting mode, the channel is inactive until a
trigger event is detected (on tim_trgi signal). Then, a comparison is performed as in
PWM mode 2 and the channels becomes inactive again at the next update. In down-
counting mode, the channel is active until a trigger event is detected (on tim_trgi
signal). Then, a comparison is performed as in PWM mode 1 and the channels
becomes active again at the next update.
1010: Reserved.
1011: Reserved.
1100: Combined PWM mode 1 - tim_oc1ref has the same behavior as in PWM mode 1.
tim_oc1refc is the logical OR between tim_oc1ref and tim_oc2ref.
1101: Combined PWM mode 2 - tim_oc1ref has the same behavior as in PWM mode 2.
tim_oc1refc is the logical AND between tim_oc1ref and tim_oc2ref.
1110: Asymmetric PWM mode 1 - tim_oc1ref has the same behavior as in PWM mode 1.
tim_oc1refc outputs tim_oc1ref when the counter is counting up, tim_oc2ref when it is
counting down.
1111: Asymmetric PWM mode 2 - tim_oc1ref has the same behavior as in PWM mode 2.
tim_oc1refc outputs tim_oc1ref when the counter is counting up, tim_oc2ref when it is
counting down.
Note: In PWM mode, the tim_ocref_clr level changes only when the result of the comparison
changes or when the output compare mode switches from “frozen” mode to “PWM”
mode.